Features:
This is an Auto-ranging digital multimeter using double-integral style A/D transform as the core.
It
can be used to measures AC/DC Voltage, AC/DC Current,Resistance,
Capacitance, Diode and Continuity testing, Temperature, Frequency,Square
Wave test,battery voltage test,V.F.C test,Dangerous voltage alarm.
They
are battery powered. They are characterized by stable function and high
reliability, with the features of overload protection and Large LCD
display for clear reading,Flashlight lighting,are an ideal tools for
lav,factory,radio fans and family use.
ANENG V7 | ANENG V8 |
Intelligent recognition/manual range | Auto range/Manual range |
Display: 6000 Counts | Display: 8000 Counts |
NCV Test | NCV Test |
not support V.F.C | Suppoort V.F.C (Can measure the voltage output of the inverter) |
Square wave output | Square wave output |
HD Backlight Screen | HD Black EBTN screen |
not support 3 three kinds of display | Voltage/Temperature have 3 three kinds of display |
Not support Analog bar graph | Analog bar graph |
TRUE RMS | TRUE RMS |
Diode test | Diode test |
Continuity test | Continuity test |
Data Hold | Data Hold |
Relative value measurement | Relative value measurement |
Display shows maximum/minimum readings | Display shows maximum/minimum readings |
Temperature test (Fahrenheit/Celsius) | Temperature test (Fahrenheit/Celsius) |
Duty cycle test | Duty cycle test |
Resistance/Power/ Frequency Test | Resistance/Power/ Frequency Test |
DC/AC voltage/current measurement | DC/AC voltage/current measurement |
Low battery prompt | Low battery prompt |
Live wire and Null wire test | Live wire and Null wire test |
Input resistance: 1MΩ | Input resistance: 10MΩ |
Specification:
Update Rate:3 times/second
Data Hold:YES
Backlight:YES
Flashlight lighting: YES
Auto Power Off:YES
Material:ABS/PVC
Operating temperature:0-40℃
Operating humidity:less then 75%
Storage temperature:-20~60℃
Operating humidity:less then 80%
Battery type :1.5V AA battery*3 (Not include)
V7 Measuring range:
DC Voltage (V)/(mV): 600.0mV/6.000V/60.00V/600.0V/1000V ±(0.5%+3)
AC Voltage (V)/(mV): 600.0mV/6.000V/60.00V/600.0V/750V ±(1.0%+3)
DC Current (A): 6.000A/20.00A ±(1.2%+3)
DC Current (mA): 6.000mA/60.00mA/600.0mA ±(1.2%+3)
DC Current (μA): 600.0μA ±(1.2%+3)
AC Current (A): 6.000A/20.00A ±(1.5%+3)
AC Current (mA): 6.000mA/60.00mA/600.0mA ±(1.5%+3)
AC Current (μA): 600.0μA ±(1.5%+3)
Resistance: 600.0Ω/6.000kΩ/60.00kΩ/600.0kΩ/6.000MΩ (0.5%+3)
60.00MΩ ±(1.5%+3)
Capacitance: 9.999nF ±(5.0%+20)
99.99nF/999.9nF/9.999μF/99.99μF/999.9μF ±(2.0%+5)
9.999mF ±(5.0%+5)
Frequency: 9.999Hz/99.99Hz/999.9Hz/9.999kHz ±(0.1%+2)
Duty Cycle: 1%~99% ±(0.1%+2)
Temperature (-20~1000)℃/(-4~1832)℉ ±(2.5%+5)
Diode:YES
Continuity:YES
Square Wave Output: 50Hz~5000Hz
Battery Test: 1.5V 9V 12V
load Current: 10mA 10mA 120mA
Dump Energy: Green ≧1.30V ≧7.83V ≧10.44V
Yellow 0.94V-1.29V 5.64V-7.82V 7.52V-10.43V
Red 5.64V-7.82V 0.90V-5.63V 1.2V-7.51V
No light ≦0.14V ≦0.89V ≦1.19V
V8 Measuring range:
DC Voltage (V)/(mV): 800.0mV/8.000V/80.00V/800.0V/1000V ±(0.5%+3)
AC Voltage (V)/(mV): 800.0mV/8.000V/80.00V/800.0V/750V ±(1.0%+3)
DC Current (A): 8.000A/20.00A ±(1.2%+3)
DC Current (mA): 8.000mA/80.00mA/800.0mA ±(1.2%+3)
DC Current (μA): 800.0μA/8000μA ±(1.2%+3)
AC Current (A): 8.000A/20.00A ±(1.5%+3)
AC Current (mA): 8.000mA/80.00mA/800.0mA ±(1.5%+3)
AC Current (μA) 800.0μA/8000μA ±(1.5%+3)
Resistance: 800.0Ω/8.000kΩ/80.00kΩ/800.0kΩ/8.000MΩ ±(0.5%+3)
80.00Ω ±(1.5%+3)
Capacitance: 9.999nF ±(5.0%+5)
99.99nF/999.9nF/9.999μF/99.99μF/999.9μF ±(2.0%+5)
9.999mF/99.99mF ±(5.0%+5)
Frequency: 9.999Hz/99.99Hz/999.9Hz ±(0.1%+2)
Duty Cycle: 1%~99% ±(0.1%+2)
Temperature: (-20~1000)℃/(-4~1832)℉ ±(2.5%+5)
Diode: YES
Continuity: YES
Square Wave Output: 50Hz~5000Hz
Package included:
1 x Multimeter
1 x Test Leads
1 x Thermocouple
1 x Protect Bag