Features:
• Insulation series digital tester which adopts low loss high ratio of inductance energy storage DC voltage converter
can change 12V voltage into 250V / 500V / 1000V / 2500V DC voltage
• Insulation series digital tester which adopts low loss high ratio of inductance energy storage DC voltage converter
can change 12V voltage into 250V / 500V / 1000V / 2500V DC voltage
• Uses digital LCR Bridge for resistance measurement and the insulation resistance test
• Advantages:
light, wide measuring range, backlight display, test lock, auto power
off (only for MAX DC1000V OUT function) and other functions
• Used for electricity measurement with
great advanced appearance, stable performance. Based on straps design,
you can operate with both hands
• Applied in motors, cables, mechanical and electrical equipment, telecommunications equipment, power facilities
and other insulation resistance testing areas
and other insulation resistance testing areas
• With automatic shutdown function (only for MAX DC1000V OUT function, about 15 minutes after machine start)
• Alarm function: The meter will alarm automatically when the measured resistance is lower than the lower limit of measuring range,
and the reading is invalid (only for only for MAX DC2500V OUT function)
►Click here to download the user manual
Specifications:
• Alarm function: The meter will alarm automatically when the measured resistance is lower than the lower limit of measuring range,
and the reading is invalid (only for only for MAX DC2500V OUT function)
►Click here to download the user manual
Specifications:
- Display: 90 × 48mm LCD display, the maximum display is "1999".
- Over range indication: Only the highest digit shows "1" when the upper limit is exceeded.
- Measurement method: Double integral type A / D conversion.
- Sampling rate: About 3 times /second
- Power supply: 5 # battery LR6 (1.5V) × 8 (Battery Not Included)
- It contains lack of voltage indication when the voltage is not enough
- Power consumption: Power consumption of empty load test <300mw
- It contains lack of voltage indication when the voltage is not enough
- Power consumption: Power consumption of empty load test <300mw
- Using environment: Temperature 0 ℃ -40 ℃, humidity 30% RH-85% RH
- Dimensions: 175(L)x110(W)x70(D)mm
Package Included:
1 x Digital Insulation Resistance Tester